欧美肉欲K8播放毛片,久久久国产精品无码免费专区,国产欧美日韩一区二区三区,中文无码日韩欧

  • 1
產(chǎn)品資料

美國(guó)戴安Dionex CarboPac PA200 Carbohydrate Column 062895 生物色譜柱

如果您對(duì)該產(chǎn)品感興趣的話,可以
產(chǎn)品名稱: 美國(guó)戴安Dionex CarboPac PA200 Carbohydrate Column 062895 生物色譜柱
產(chǎn)品型號(hào): 062895
產(chǎn)品展商: 戴安Dionex
產(chǎn)品文檔: 無(wú)相關(guān)文檔

簡(jiǎn)單介紹

戴安公司生產(chǎn)的儀器主要有離子色譜儀、高效液相色譜儀、快速溶劑萃取儀和氨基酸直接分析儀。其中離子色譜儀憑借著雄厚的技術(shù)優(yōu)勢(shì)和方法已廣泛地應(yīng)用于各個(gè)領(lǐng)域,其市場(chǎng)占有率達(dá)80%。全球與離子色譜相關(guān)的文章有90%均出自戴安公司生產(chǎn)的離子色譜儀。   戴安公司的快速溶劑萃取儀15分鐘之內(nèi)僅用15毫升溶劑既可完成對(duì)10g樣品的萃取,該技術(shù)已在環(huán)境、**、食品和聚合物工業(yè)等領(lǐng)域得到廣泛應(yīng)用。


美國(guó)戴安Dionex CarboPac PA200 Carbohydrate Column 062895 生物色譜柱  的詳細(xì)介紹

Fast, pH-Stable Separation of Oligosaccharides

A variety of HPLC approaches are proposed for characterizing oligosaccharides, but many prove inadequate for separating complex mixtures and are limited by a lack of specificity and high limits of detection. Dionex has developed an improved HPLC technique for carbohydrate analysis based on anion-exchange chromatography coupled with pulsed amperometric detection. This technique provides high-resolution separations with sensitive and specific detection, without derivatization.

  • Sensitive, direct detection with no derivatization, using pulsed amperometric detection
  • Very high-efficiency separations
  • Separations based on size, charge, degree of branching, and linkage isomerism
  • Low flow rate saves on eluent consumption
  • Does not require derivatization

CarboPac? PA200 columns are packed with a hydrophobic, polymeric, pellicular anion-exchange resin stable over the range of pH 0–14. The unique pH-stability of the packing material allows the use of eluent compositions that are conducive to anodic oxidation of carbohydrates at gold electrodes.

CarboPac PA200 Column for High-Resolution Oligosaccharide Separations Specifications
Dimensions CarboPac? PA200 Analytical Column:
3 × 250 mm
CarboPac PA200 Guard Column:
3 × 50 mm
Maximum operating pressure 4000 psi (27.9 MPa)
Temperature range 6–60 °C  
Recommended operating temperature: controlled ambient
Typical operating conditions 2700 psi at 0.5 mL/min (analytical and guard columns)
Recommended flow rate: 0.5 mL/min
Mobile phase compatibility pH 0–14; 100% compatible with common organic solvents. 
Ionic form eluents: sodium acetate and sodium hydroxide only.
Resin composition 5.5 μm-diameter ethylvinylbenzene/divinylbenzene substrate (55% cross-linked) agglomerated with 43 nm MicroBead? quaternary amine functionalized latex (6% crosslinked)
Anion-exchange capacity Approximately 35 μeq/column (3 × 250 mm analytical column)
Column construction PEEK? with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic
Guard Columns
CarboPac PA200 Guard Column (3 x 50 mm) 062895
Analytical Columns
CarboPac PA200 Analytical Column (3 x 250 mm) 062896

產(chǎn)品留言