CarboPac PA10 Carbohydrate Column
For Sensitive Analysis of Mono- and Disaccharides
The Thermo
Scientific? CarboPac? PA10 column line has been expanded to include a
new 0.4 × 250 mm capillary column. As with all CarboPac PA10 columns,
the new capillary format is the ideal choice for mono- and disaccharides
in foods, drugs and plants.
The CarboPac PA10 is an ideal choice
for separations of mono- and disaccharides found in mammalian
glycoproteins. Fucose is well resolved from the system void and from
protein hydrolysate interferents. The CarboPac PA10 allows oxygen to
elute after mannose, eliminating interference with monosaccharides. It
is ideal for the analysis of mono- and disaccharides in foods, drugs,
and plants, and separates sialic acids with the addition of sodium
acetate to the eluent.
-
For the quantification of acidic, neutral, and aminomonosaccharides
-
Simple, isocratic separations
-
Superior selectivity for common monosaccharides compared to the CarboPac PA1
-
No derivatization required
-
Gradient compatible
The
CarboPac PA10 is an anion-exchange column designed specifically for
high-resolution separations of mono- and disaccharides. Separation is
accomplished with a simple isocratic eluent, and detection is
accomplished with pulsed amperometric detection (PAD). No derivatization
is required.
CarboPac PA10 Column for Monosaccharide and Disaccharide Analysis Specifications
|
Dimensions
|
CarboPac PA10 Analytical Column:
4 × 250 mm, 2 × 250 mm and 0.4 × 250 mm
CarboPac PA10 Guard Column:
4 × 50 mm, 2 × 50 mm and 0.4 × 50 mm
|
Maximum operating pressure
|
3500 psi (24.5 MPa)
|
Temperature range
|
4–55 °C
Recommended operating temperature: ambient
|
Typical operating conditions
|
1900 psi at 1.0 mL/min (4 mm analytical and guard columns)
Recommended flow rate: 1.0 mL/min (4 mm), 0.25 mL/min (2 mm) or 0.010 mL/min (0.4 mm)
|
Mobile phase compatibility
|
pH 0–14; up to 90% of common HPLC solvents.
Avoid anionic detergents and 100% water.
Acetate or hydroxide eluents only.
|
Resin composition
|
10-μm diameter substrate (ethylvinylbenzene 55% cross-linked with divinylbenzene) agglomerated with 460-nm MicroBead? difunctional quaternary ammonium ion (5% cross-linked).
|
Anion-exchange capacity
|
Approximately:
100 μeq/column (4 × 250 mm analytical column)
25 μeq/column (2 × 250 mm analytical column)
1 μeq/column (0.4 × 250 mm analytical column)
|
Column construction
|
PEEK with 10-32 threaded ferrule-style end fittings.
All components are nonmetallic.
|
Analytical Columns
|
CarboPac PA10 Analytical Column (2 x 250 mm)
|
057180
|
CarboPac PA10 Analytical Column (4 x 250 mm)
|
046110
|
CarboPac PA10 Semi-Preparative (9 X 250 mm)
|
SP4216
|
Guard Columns
|
CarboPac PA10 Guard Column (2 x 50 mm)
|
057181
|
AminoTrap Column (2 x 50 mm)
|
SP5578
|
CarboPac PA10 Guard Column (4 x 50 mm)
|
046115
|
Amino Trap Column (4 x 50 mm)
|
046122
|
Borate Trap Column
|
047078
|
Amino Trap Column (3 x 30 mm)
|
060146
|